Skip to main content
GAGGENAU logo
CG492110F

Product is no longer available

More information and services related to this product

1 / 0
Photo Nr. 1 of the product CG492110F
Photo Nr. 2 of the product CG492110F
Photo Nr. 3 of the product CG492110F
Photo Nr. 4 of the product CG492110F
Photo Nr. 5 of the product CG492110F
Photo Nr. 6 of the product CG492110F
Photo Nr. 7 of the product CG492110F
Photo Nr. 8 of the product CG492110F
Photo Nr. 9 of the product CG492110F

Specifications

Up to 17 kW on 5 burners
Solid smooth-surface cast iron pan supports on the same level as the worktop
Automatic fast ignition, electronic flame monitoring
1 three-ring wok burner (300 W – 5000 W), suitable for pots up to max. ø 32 cm.
2 two-ring high output burners (160 W – 4000 W), suitable for pots up to max. ø 28 cm.
2 two-ring standard burners (160 W – 2000 W), suitable for pots up to max. ø 24 cm.
Control knobs with cooking zone and output level markings.
One-handed operation.
Three-part cast iron pan support with flat, continous pot surface, on the same level as the worktop.
Brass burner rings.
Electronic flame monitoring with automatic re-ignition.
Automatic fast ignition.
The frame set (necessary installation accessory) can be sent in advance to the manufacturer of the stainless steel or granite worktop for fitting.
Special nozzles can be ordered as spare parts.
Plan for an electrical connection (the appliance is not operable without power supply).
Panel thickness 16 - 26 mm.
The drawing "Installation of the control knob" must be observed if the panel is more than 26 mm thick (there must be a recess at the rear).
Minimum worktop depth 70 cm.
Control knobs can be integrated in the lower cabinet at drawer level.
Air intake from above.
No intermediate shelf required.
Due to the separate frame welded into the worktop, all parts remain fully accessible.
Rear panel and wall trims must be heat-resistant and consist of a non-flammable material.
The appliance can be fixed from above.
A minimum lateral clearance of at least 300 mm from adjacent heat-sensitive furniture or contact surfaces must be observed or thermal insulation fitted.
Cooktop clamping range: 40 - 50 mm.
With a total connected load of more than 11 kW local regulations concerning room ventilation, room size and combination of extraction or recirculation hoods must be observed. Minimum clearance between gas cooktop(s) with more than 11 kW and ventilation hood 70 cm.
The combination with VL 414 is not recommended, since the air extraction from the centre burner cannot be guaranteed due to the distance.
Total connected load gas 17.0 KW.
Connecting cable 1.4 m with plug.