VL 431

VL 431

Detailed view
  • Ventilation element integrated in the worktop
  • Highly efficient ventilation system at the cooktop
  • Compact ducting in connection with flat rectangular pipes AD 8..
  • With sealing flaps
  • Minimal planning and easy installation for air recirculation

Output

  • Maximum air output in combination with remote fan units s. table remote fan units on page xxx.
  • Sound power level depends on the built-in situation.

Features

  • Output control, touch key operation.
  • 2 output levels.
  • Run-on function; duration approx. 22 minutes.
  • Automatically continued run-on in the “0” position for approx. 15 seconds.
  • Automatic sealing flaps over ventilation slit.
  • Metal grease filter with grease collecting insert.
  • Additional switch for connection to AR.
  • Duct connection piece DN 125 cylindric.

Planning notes

  • Air extraction operation in combination with remote fan units AR 400/401 or recirculation mode with AR 413.
  • Please refer to page xxx for recommended configurations of downdraft ventilations and remote fan units and the needed ducting elements.
  • Maximum cooktop width between two VL: 60 cm.
    Maximum distance between cut-outs: 5 cm.
  • The air baffle LS 330 000 is mandatory for installation next to gas appliances to avoid hazard of fire by saturated grease filters.
  • Do not operate VL 431/430 next to VG 411 gas wok.
  • When installing a ventilation hood with air extraction mode or recirculation outlet in another area of room air (e.g. cellar) and a chimney-vented fireplace, the hood's power supply line needs a suitable safety switch.
  • Store the control electronics box (250 x 145 x 54 mm) for VL 431 in the lower cabinet.
  • For installation in stone or light-coloured plastic worktops, use sealing tape (part No. 322793).
  • For maximum duct lengths use Gaggenau flat rectangular ducts AD 8… or Naber-System Compair flow. Other flat ducts are not permitted!
  • Duct connection downwards or sidewards:
    DN 125 cylindrical included.
    Optional DN 125/150 flat rectangular duct with connection piece AD 824/854 042 (installation accessory).
  • Connection of 2 VL with ducting
    2x DN 125 cylindrical or 2x DN 125/150 rectangular at remote fan AR 4.. .
    For leading through the floor DN 150 cylindrical with connection of 2 DN 125 cylindrical use Y-joint AD 754 044.
  • Please ensure when installing the exhaust air ducting that no sharp bends are caused and that the cross-section of the ducting is not constricted in any way.
  • For downdraft configurations with maximum lengths of exhaust air ducts go to Rodun at www.gaggenau.com.

Connection

  • Connecting cable 1.5 m with plug.